Abstract
The automotive industry is currently driven by the megatrends electrification, automated driving and connectivity. To cope with these trends, new functionalities and electrical and/or electronic (E/E) systems need to be developed and deployed. Independent of the implementation of E/E systems, their power input shall be ensured by the power supply system as a shared resource – leading to increased functional safety requirements for power supply systems. If the loss of an item’s functionality can lead to a hazardous event, a safety goal (SG) specifying a safety-related availability (SaRA) requirement is derived. Thereby, switching to passive mode typically cannot be considered a safe state. To address an SG specifying a SaRA requirement, fault avoidance, fault forecasting and/or fault tolerance measures can be applied. In the case of fault tolerance measures implemented by redundancy, which leads to fail-active behavior, the performance of the backup system during nominal operation and after the first fault can be further refined. In this study, SaRA in the context of ISO 26262 is evaluated in detail and mapped to an example of the power supply domain.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.