Abstract

To evaluate the safety of ultrasound-guided percutaneous mesenteric vein access compared to transsplenic portal vein access for portosystemic shunt placement in patients with portal vein obstruction. Eight patients underwent portosystemic shunt creation through either a transsplenic (n = 4) or transmesenteric (n = 4) approach. The superior or inferior mesenteric vein was percutaneously accessed under ultrasound guidance using a 21G needle and a 4F sheath. Hemostasis at the mesenteric access site was achieved with manual compression. For transsplenic access, sheath sizes between 6 and 8F were used and tract embolization with gelfoam was performed. Portosystemic shunt placement was successful in all patients. While there were no bleeding complications with transmesenteric access, hemorrhagic shock requiring splenic artery embolization occurred in one patient in which the transsplenic approach was used. Ultrasound-guided mesenteric vein access seems feasible and a valid alternative to the transsplenic access in case of portal vein obstruction. Level of Evidence Level 4, case series.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.