Abstract

ObjectivesThe aim of this study was to assess safety outcomes of femoropopliteal drug-coated balloon (DCB) angioplasty using patient-level data from the Lutonix clinical program. BackgroundA recent systematic review and meta-analysis of heterogenous trials and summary-level data identified increased long-term mortality in patients treated with paclitaxel-coated balloons and stents. MethodsWe evaluated DCB angioplasty (n = 1,093) and uncoated balloon angioplasty (percutaneous transluminal angioplasty [PTA]) (n = 250) outcomes in LEVANT 1 (The Lutonix Paclitaxel-Coated Balloon for the Prevention of Femoropopliteal Restenosis), LEVANT 2 (Moxy Drug Coated Balloon vs. Standard Balloon Angioplasty for the Treatment of Femoropopliteal Arteries), and the LEVANT Japan Clinical Trial. Hazard ratios (HRs) were calculated with Cox proportional hazards modeling. ResultsThere were no significant differences in mortality rates between DCB angioplasty and PTA. The 5-year HR was 1.01 (95% confidence interval [CI]: 0.68 to 1.52) in the aggregated LEVANT trials. The 2-year HR after DCB angioplasty was 0.99 (95% CI: 0.25 to 3.95) in LEVANT 1, 1.40 (95% CI: 0.62 to 3.14) in LEVANT 2, and 0.32 (95% CI: 0.05 to 1.92) in the LEVANT Japan Clinical Trial. The 5-year HR was 1.60 (95% CI: 0.94 to 2.72) in LEVANT 2. Adverse events and causes of death were balanced, without clustering between DCB angioplasty and PTA. Patients who underwent paclitaxel or nonpaclitaxel reinterventions had higher survival rates than those who did not undergo reinterventions. Baseline covariates predicting mortality included, among others, age (HR: 1.03 per year; p < 0.0001), prior treatment of target lesion (HR: 1.67; p = 0.022), arrhythmia (HR: 1.65; p = 0.031), and diabetes (HR: 1.18; p = 0.047), without differences between the 2 arms. No dose-response relationship was identified when adjusted for key predictors of mortality. ConclusionsAnalyses of patient-level data identified no mortality differences between DCB angioplasty and PTA. Furthermore, the lack of dose-response relationships or clustering of causes of death argues against a causal relationship between paclitaxel and mortality. (LEVANT 1, The Lutonix Paclitaxel-Coated Balloon for the Prevention of Femoropopliteal Restenosis [LEVANT 1], NCT00930813; Moxy Drug Coated Balloon vs. Standard Balloon Angioplasty for the Treatment of Femoropopliteal Arteries [LEVANT 2], NCT01412541; LEVANT 2 Continued Access Registry, NCT01628159; LEVANT Japan Clinical Trial, NCT01816412)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.