Abstract

To provide a comprehensive and contemporary overview of the long-term safety outcomes after aortic valve replacements (AVR) with conventional biological heart valve (stented or stentless). English databases (Medline, Embase, Web of Science, CENTRAL, and ClinicalTrial.gov) and Chinese databases (CNKI, VIP, WanFang, and SinoMed) were searched systemically from January 1, 2000 to January 26, 2019. Eligible randomized controlled trials, non-randomized clinical trials, cohort studies (retrospective or prospective), and unselected case series were included. Strict screening of the obtained literature was conducted to extract relevant data by two reviewers. Other inclusion criteria were studied reporting on outcomes of AVR with biological valves (stented or stentless), with or without coronary artery bypass grafting (CABG) or valve repair procedure, with mean follow-up length equal to or longer than 5 years. We excluded studies that reported only a specific patient group (e.g., patients with renal failure, or pregnancy), without the report of biological valve type, or with study population size less than 100. The meta-analysis was performed using Stata 14.0 software. In this study, 53 papers (in total 57 study groups) involving 47 803 patients were included. (1) The all-cause mortality was 6.33/100 patient-years (95%CI: 5.85-6.84). Subgroup analysis showed that the mortality rates of porcine and bovine valve prostheses were 5.69/100 patient-years (95%CI: 5.05-6.41) and 7.29/100 patient-years (95%CI: 6.53-8.13), respectively. The all-cause mortality rates for stented and stentless valve were 6.69/100 patient-years (95%CI: 6.12-7.30) and 5.21/100 patient-years (95%CI: 4.43-6.14), respectively. (2) The incidence rate of thromboembolism was 1.16/100 patient-years (95%CI: 0.96-1.40), the incidence rate of permanent pacemaker (PPM) implantation was 1.08/100 patient-years (95%CI: 0.75-1.54), the incidence rate of stroke was 0.74/100 patient-years (95%CI: 0.51-1.06), the incidence rate of structural valve dysfunction (SVD) was 0.73/100 patient-years (95%CI: 0.59-0.91), the incidence rate of major bleeding was 0.52/100 patient-years (95%CI: 0.41-0.65), the incidence rate of endocarditis was 0.38/100 patient-years (95%CI: 0.33-0.44), and the incidence rate of non-structural valve dysfunction (NSVD) was 0.20/100 patient-years (95%CI: 0.13-0.31). The total reoperation rate for biological aortic valve was 0.77/100 patient-years (95%CI: 0.65-0.91), and the SVD related reoperation rate was 0.46/100 patient-years (95%CI: 0.36-0.58). The all-cause mortality for conventional biological AVR was 6.33/100 patient-years. Thromboembolism, PPM implantation, reoperation, stroke, and SVD were major long term complications.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.