Abstract
Wearable sensors in digital health may pose a risk for skin irritation through the use of wearable patches. Little is known about how patient- and product-related factors impact the risk of skin irritation. Aripiprazole tablets with sensor (AS, Abilify MyCite; Otsuka America Pharmaceutical, Inc) is a digital medicine system indicated for the treatment of patients with schizophrenia, bipolar I disorder, and major depressive disorder. AS includes aripiprazole tablets with an embedded ingestible event marker, a wearable sensor attached to the skin through a wearable patch, a smartphone app, and a web-based portal. To continuously improve the final product, successive iterations of wearable patches were developed, including raisin patch version 4 (RP4), followed by disposable wearable sensor version 5 (DW5), and then reusable wearable sensor version 2 (RW2). This analysis pooled safety data from clinical studies in adult participants using the RP4, DW5, and RW2 wearable patches of AS and evaluated adverse events related to the use of wearable patches. Safety data from 12 studies in adults aged 18-65 years from May 2010 to August 2020 were analyzed. All studies evaluated safety, with studies less than 2 weeks also specifically examining human factors associated with the use of the components of AS. Healthy volunteers or patients with schizophrenia, bipolar I disorder, or major depressive disorder were enrolled; those who were exposed to at least 1 wearable patch were included in the safety analysis. Adverse events related to the use of a wearable patch were evaluated. Abrasions, blisters, dermatitis, discoloration, erythema, irritation, pain, pruritus, rash, and skin reactions were grouped as skin irritation events (SIEs). All statistical analyses were descriptive. The analysis included 763 participants (mean [SD] age 42.6 [12.9] years; White: n=359, 47.1%; and male: n=420, 55%). Participants were healthy volunteers (n=269, 35.3%) or patients with schizophrenia (n=402, 52.7%), bipolar I disorder (n=57, 7.5%), or major depressive disorder (n=35, 4.6%). Overall, 13.6% (104/763) of the participants reported at least 1 SIE, all of which were localized to the wearable patch site. Incidence of ≥1 patch-related SIEs was seen in 18.1% (28/155), 14.2% (55/387), and 9.2% (28/306) of participants who used RP4, DW5, and RW2, respectively. Incidence of SIE-related treatment discontinuation was low, which is reported by 1.9% (3/155), 3.1% (12/387), and 1.3% (4/306) of participants who used RP4, DW5, and RW2, respectively. The incidence rates of SIEs reported as the wearable patch versions evolved from RP4 through RW2 suggest that information derived from reported adverse events may have informed product design and development, which could have improved both tolerability and wearability of successive products. Clinicaltrials.gov NCT02091882, https://clinicaltrials.gov/study/NCT02091882; Clinicaltrials.gov NCT02404532, https://clinicaltrials.gov/study/NCT02404532; Clinicaltrials.gov NCT02722967, https://clinicaltrials.gov/study/NCT02722967; Clinicaltrials.gov NCT02219009, https://clinicaltrials.gov/study/NCT02219009; Clinicaltrials.gov NCT03568500, https://clinicaltrials.gov/study/NCT03568500; Clinicaltrials.gov NCT03892889, https://clinicaltrials.gov/study/NCT03892889.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.