Abstract

Aim: This pooled analysis evaluated the safety and tolerability of the subcutaneous immunoglobulin 20% product, Ig20Gly, in primary immunodeficiency diseases using data from two Phase II/III studies conducted in North America and Europe. Patients & materials/methods: Patients received Ig20Gly (volumes, ≤60ml/site; rates, ≤60ml/h/site). Adverse events (AEs), tolerability and infusion parameters were assessed. Results: Patients (2-83years; N=122) received 6676 Ig20Gly infusions. No causally related serious or severe AEs were reported. Thirty-five patients (28.7%) reported 232 causally related local AEs. Twenty-seven patients (22.1%) reported 165 causally related systemic AEs. There was no association between the infusion volume or rate and causally related local AEs. Conclusion: Ig20Gly was well tolerated in a broad population of patients with primary immunodeficiency diseases.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.