Abstract

To investigate feasibility and safety of stereotactic ablative radiotherapy in the management of prostate cancer while employing MR/CT fusion for delineation, fiducial marker seeds for positioning and Varian RapidArc with flattening filter free (FFF) delivery. 41 patients were treated for low-intermediate risk prostate cancer with initial prostate-specific antigen of ≤20 ng ml-1, Gleason score 6-7. Patients had MR/CT fusion for delineation of prostate ±seminal vesicles. CT/MR fusion images were used for delineation and planned using flattening filter free modality. Verification on treatment was cone beam CT imaging with fiducial markers for matching. Patients had Radiation Therapy Oncology Group scoring for genitourinary and gastointestinal symptoms at baseline, week 4, 10 and 18. Clinically acceptable plans were achieved for all patients, all plans achieved the objective clinical target volume D99% ≥ 95%, and for planning target volume D95% ≥ 95%. Rectum dose constraints were met for 95.1% for V18 Gy ≤ 35%, 80% V28 Gy ≤ 10%. A total of 32 (78.0%) plans achieved all rectum dose constraints. Grade 1 acute genitourinary symptoms were 53.7% of patients at baseline, 90.2% [95% CI (76.8-97.3%)] (p = 0.0005) at treatment 5, falling to 78.0% (62.4-89.4%) at week 4, and 75.0% (58.8-87.3%) by week 10 and 52.5% (36.1-68.5%) (p = 1.00) at week 18. Acute gastrointestinal symptoms were 5% at baseline, 46.3% [95% CI (30.7-62.6%)] at treatment 5, week 4 43.9% [95% CI (28.5-60.3%)], week 10 25.0% (11.1-42.3%), and declined slightly by week 18 [-20.095% CI (12.7-41.2)] p = 0.039. Overall 75.6% (31/41) of patients experienced Grade 1-2 toxicity during or after treatment. This planning and delivery technique is feasible, safe and efficient. A homogeneous dose can be delivered to prostate with confidence, whilst limiting high dose to nearby structures. The use of this technology can be applied safely within further randomized study protocols. Advances in knowledge: Multimodality imaging for delineation and linac-based image-guided RT with FFF for the treatment of prostate stereotactic ablative radiotherapy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.