Abstract Purpose To evaluate the safety and efficacy of vacuum-assisted breast biopsy (VABB) under ultrasound and stereotactic guidance. Methods This institutionally approved retrospective analysis comprised 60 females who underwent VABB under ultrasound and stereotactic guidance. Technical success and adverse events were analyzed as per the Society of Interventional Radiology standards. Pain score was recorded as per the visual analog scale. Results Technical success was 100% with high specificity (100%), sensitivity (96%), negative predictive value 97%, and accuracy of 98%. Ductal carcinoma in situ underestimation rate was 4%. No major complications were encountered, and minor complication of postprocedural hematoma did not require intervention. Procedure was well tolerated with majority patients experiencing mild pain. Conclusion VABB under ultrasound and stereotactic guidance is a safe and effective method for sampling breast abnormalities.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.