Abstract

Percutaneous tracheostomy is used primarily to assist weaning from mechanical ventilation in the intensive care unit. We report our experiences of 800 such procedures performed in the intensive care unit by a collaborative team (critical care and ENT specialists). Most procedures (85.6%) were performed by residents supervised by the intensive care unit staff. Complications occurred in 32 patients (4%). Intraprocedural complications occurred in 17 patients (2.1%), early postprocedural complications in six (0.75%), and late postprocedural complications in nine (1.1%). No deaths were directly related to percutaneous tracheostomy. The incidence of complications was greater in percutaneous tracheostomy performed by the residents during their initial five attempts compared to their later attempts (9.2% vs 2.6%, p < 0.05). The low incidence of complications indicates that bedside percutaneous tracheostomy can be performed safely as a routine procedure in daily care of intensive care unit patients.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.