Abstract

The supercritical-pressure water-cooled fast reactor (SWFR) is a fast spectrum supercritical water-cooled reactor (SCWR) studied by the University of Tokyo. The SWFR is designed as a two-pass core with an outlet temperature 500 °C. The SWFR has fuel channels cooled by downward flow, higher power density, and smaller coolant density reactivity feedback compared with Super LWR. This paper describes the safety analyses of abnormal events for the SWFR. SPRAT-F code is used for the safety analysis at supercritical pressure considering the downward flow cooled seed fuel channel. This code is based on a 1-D node junction model with point kinetics and decay heat calculations. Flow redistribution among parallel paths is calculated by pressure-loss balance and momentum conservation. The initiating events are selected from those of LWRs. For the safety analysis, nine abnormal transients and four accidents are selected with considering types of abnormality. By the numerical analyses, it was found that the loss of flow events can be mitigated by the “water source” effect of the downward flow blanket channels in the abnormal transients and accidents. All the abnormal events satisfy the criteria with margin.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call