Abstract
In this paper an integral pressurized water reactor (IPWR) has 100 MW capacity with passive safety features. The design of IPWR focuses on enhancing the safety and reliability of the reactor by employing inherent safety features such as low core power density, elimination of large break loss of coolant accident, etc. In addition, in order to prevent the progression of emergency situations into accident, IPWR is provided with a number of engineered safety features such as passive residual heat removal system (PRHRS).This paper presents an overview of the IPWR design, and results of over-pressure accident analyses. The results of the accident analyses show that IPWR provides the inherent over-pressure protection capability for design basis accidents without actuation of any protection devices such as safety valves, rupture disks, etc.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.