Abstract

Orbito-zygomatic craniotomy is a widely accepted skull-based technique, but osteotomy at the malar eminence (ME) is complicated. We have developed a safe fronto-orbito-zygomatic (FOZ) osteotomy by creating small guide burr holes in the superior and lateral parts of the orbital wall and cutting the bone using a diamond-coated threadwire saw. This method involves standard two-piece osteotomy by creating small superior and lateral guide orbital burr holes instead of sectioning into the superior and inferior orbital fissures. The guide burr holes are connected using a diamond-coated threadwire saw to create the FOZ bar. This method was applied to the treatment of four patients with skull-based tumors or internal carotid and basilar artery aneurysms. Postoperative three-dimensional bone density computed tomography showed minimum bone gap in the ME. No craniotomy-related complication has occurred. FOZ osteotomy by creating guide burr holes in the orbital wall and cutting the bone using a diamond-coated threadwire saw is safe and results in minimum bone gap in the ME.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.