Abstract

Background: Bronchoscopic sampling of bronchoalveolar fluid (BAL) should be safe and effective. Current sampling practice risks loss of sample to the attached negative flow, aerosolisation, or spillage, due to repeated circuit breaks, when replacing sample containers. Such concerns were highlighted during the recent coronavirus pandemic. Objectives: Evaluation of an alternative integrated sampling solution, with the Ambu Bronchosampler with aScope 4, by an experienced bronchoscopist in ICU. Methods: An observational study of 20 sequential bronchoscopic diagnostic sampling procedures was performed on mechanically ventilated patients with suspected ventilator-associated pneumonia. Mixed methods assessment was done. The predefined outcome measures were (1) ease of set up, (2) ease of specimen collection, (3) ease of protecting specimen from loss or spillage, and (4) overall workflow. The duration of the procedure and the % volume of sample retrieved were recorded. Results: The mean (±standard deviation [SD]) time for collecting 1 sample was 2.5 ± 0.8 min. The mean (±SD) specimen yield for instilled miniBAL was 54.2 ± 17.9%. Compared with standard sampling, the set-up was much easier in 18 (90%), or easier in 2 (10%) of procedures, reducing the connection steps. It was much more intuitive to use in 14 (70%), more intuitive in 4 (20%), and no more intuitive to use in 2 (10%). The overall set-up and workflow was much easier in 69% of the 13 intraprocedural connections and easier or as easy in the remaining 31% procedures. All procedures where pre connection was established were much easier (7, 100%). The Ambu Bronchosampler remained upright in all procedures with no loss or spillage of sample. Obtaining a sample was much easier in 60%, easier in 10%, no different in 20%, and worse in 10%. The ability to protect a sample from start to finish compared to standard procedures was much easier in 80%, easier in 15%, and no different in 5% of procedures. Overall workflow was much easier in 14 (70%), easier in 4 (20%), and no different in 2 (10%) of procedures. Conclusions: The Ambu Bronchosampler unit was a reliable, effective, and possibly safer technique for diagnostic sampling in ICU. It may improve safety standards during the coronavirus pandemic. A randomized control trial against the standard sampling technique is warranted.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.