Abstract
BackgroundStress fractures are injuries caused by repetitive loading during activities such as running. The application of advanced analytical methods such as machine learning to data from multiple wearable sensors has allowed for predictions of biomechanical variables associated with running-related injuries like stress fractures. However, it is unclear if data from a single wearable sensor can accurately estimate variables that characterize external loading during running such as peak vertical ground reaction force (vGRF), vertical impulse, and ground contact time. Predicting these biomechanical variables with a single wearable sensor could allow researchers, clinicians, and coaches to longitudinally monitor biomechanical running-related injury risk factors without expensive force-measuring equipment.PurposeWe quantified the accuracy of applying quantile regression forest (QRF) and linear regression (LR) models to sacral-mounted accelerometer data to predict peak vGRF, vertical impulse, and ground contact time across a range of running speeds.MethodsThirty-seven collegiate cross country runners (24 females, 13 males) ran on a force-measuring treadmill at 3.8–5.4 m/s while wearing an accelerometer clipped posteriorly to the waistband of their running shorts. We cross-validated QRF and LR models by training them on acceleration data, running speed, step frequency, and body mass as predictor variables. Trained models were then used to predict peak vGRF, vertical impulse, and contact time. We compared predicted values to those calculated from a force-measuring treadmill on a subset of data (n = 9) withheld during model training. We quantified prediction accuracy by calculating the root mean square error (RMSE) and mean absolute percentage error (MAPE).ResultsThe QRF model predicted peak vGRF with a RMSE of 0.150 body weights (BW) and MAPE of 4.27 ± 2.85%, predicted vertical impulse with a RMSE of 0.004 BW*s and MAPE of 0.80 ± 0.91%, and predicted contact time with a RMSE of 0.011 s and MAPE of 4.68 ± 3.00%. The LR model predicted peak vGRF with a RMSE of 0.139 BW and MAPE of 4.04 ± 2.57%, predicted vertical impulse with a RMSE of 0.002 BW*s and MAPE of 0.50 ± 0.42%, and predicted contact time with a RMSE of 0.008 s and MAPE of 3.50 ± 2.27%. There were no statistically significant differences between QRF and LR model prediction MAPE for peak vGRF (p = 0.549) or vertical impulse (p = 0.073), but the LR model’s MAPE for contact time was significantly lower than the QRF model’s MAPE (p = 0.0497).ConclusionsOur findings indicate that the QRF and LR models can accurately predict peak vGRF, vertical impulse, and contact time (MAPE < 5%) from a single sacral-mounted accelerometer across a range of running speeds. These findings may be beneficial for researchers, clinicians, or coaches seeking to monitor running-related injury risk factors without force-measuring equipment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.