Abstract
Introduction: Management of ingested foreign bodies is a challenging task given differences in type and presentation. Ingested button batteries cause injury via electrical discharge, corrosive contents, and toxicity. The European Society of Gastrointestinal Endoscopy recommends endoscopic retrieval within 12-24 hours for objects longer than 6 cm. Conservative monitoring can be instituted for blunt objects less than 6 cm in length and 2.5 cm in diameter, or post pyloric. Due to risks of fistulas, perforation, and vocal cord paralysis, ingested button battery cases are handled emergently. However, we present an unusual case that demonstrated significantly delayed endoscopic removal of an ingested button battery without complication. Case Description/Methods: A 45-year-old male with no medical history presented 4 days after ingestion of ‘2 magnets’. He had dysphagia and difficulty eating solid foods, but remaining review of systems was negative. He denied tobacco or alcohol use, and no family history of gastrointestinal cancers. Vitals were normal. His abdomen was benign. Visualization of his oropharynx was unremarkable. Labs did not demonstrate leukocytosis or anemia. Imaging revealed one radiopaque body in the esophagus at T1 level and one in the rectum. Endoscopic removal of the object was delayed until day 6 given patient’s initial refusal. A 20mm button battery was found in the esophagus and removed with a roth net (Figure panel 1). Mild localized mucosal necrosis was noted underlying the object (Figure panel 2). He tolerated oral intake later that evening. Discussion: The management of foreign bodies is a challenge due to technical difficulties of endoscopic retrieval and unpredictable outcomes. As seen in this case, the excessive duration of time post button battery ingestion did not correlate to severity and complications expected. Despite its larger diameter of 20 mm, the button battery only caused mild mucosal necrosis. This case demonstrates that esophageal dwell time alone is not an independent risk factor and may not correlate with severity of injury. There are risks associated with performing emergent endoscopic procedures including availability of staff, abbreviated time for full preoperative evaluation, and logistic challenges. It is important to identify when procedures can be performed under controlled circumstances. Our case contributes to the fund of knowledge regarding delayed endoscopic foreign body removal of a button battery but should not be used to guide current management without additional data.Figure 1.: 1: Identification of a 20mm button battery in the upper esophagus. 2: Mild localized necrosis of the esophageal mucosa directly underlying the object.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.