Abstract

Introduction An adequate liver biopsy should contain ≥10 portal tracts. We asked: what length of fresh tissue would guarantee enough microscopic tissue for an adequate liver biopsy after allowing for tissue shrinkage during fixation and processing? Methods Data for liver biopsies taken between 2004 and 2008 were analysed for the following: macroscopic length – length of tissue before processing, microscopic length on pathology slides, number of portal tracts in each biopsy and diagnosis. We also conducted a prospective pilot study to correlate length of fresh tissue at the time of biopsy with the length of formalin-preserved tissue at the time of arrival in the lab. Results There were 412 ultrasound-guided liver biopsies taken with 18 Fr needles in 195 females (F) and 217 males (M). Portal tracts could not be counted in the following: 98 cases of malignancy, 42 cases of cirrhosis and 14 insufficient biopsies. Of the remaining 258 biopsies, statistical analysis was performed on 192 (75%) samples where all of macroscopic length, microscopic length and number of portal tracts were recorded. The diagnoses were: 119 viral hepatitis (F=45, M=74 mean 37 years) 35 fatty liver disease (F=14, M=21 mean 49 years) 10 haemochromatosis (F=2, M=8 mean 59 years) 7 autoimmune hepatitis (F=6, M=1 mean 50 years) 6 normal liver (F=3, M=3, mean 43 years) 4 cholestatic liver disease (F=2, M=2 mean 54 years) 4 drug induced liver injury (F=3, M=1 mean 39 years) 7 others (F=5, M=2 mean 51 years). Tissue shrank consistently (r=0.837, p 99% of cases. Our pilot study of 10 consecutive biopsies showed no tissue shrinkage during transport in formalin to the lab. Conclusion The length of fresh tissue from a liver biopsy obtained using an 18 Fr needle directly correlates to the number of portal tracts in all diagnoses excluding cirrhosis and malignancy. To ensure that patients have an adequate diagnosis and avoid a repeat biopsy we suggest that operators ensure at least 18 mm of fresh liver tissue at a cut-off of 10 portal tracts and 30 mm of tissue at a cut-off of ≥15 portal tracts. We advise operators to actively measure the length of tissue at the time of the procedure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.