Small wind turbines are spreading for the purpose of independent or domestic power suppliers. However its standard of strength is still being discussed. In this paper, IEC61400-1 Ed.3 DLC (Design Load Case) 1.1 for large wind turbines is applied for a small wind turbine and estimated its applicability. DLC 1.1 requires load estimation with extrapolation for 50 year return load. Target turbine is "AIRDORPHIN GTO" and aero-elastic simulation tool FAST is used. As a result the target turbine has various load characteristic in its operation modes; normal mode and stall mode. For this reason, an extrapolation method which considers operation modes is tried and established.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.