Abstract

One of the critical issues in designing and fabricating high-performance planar solid oxide fuel cell (pSOFC) stacks is the ability to hermetically seal adjacent metal and ceramic components. In our pSOFC development program, we have designed a testing technique that allows us to screen through the numerous variables involved in developing glass seals. Using this test for example, we have found that the composition of the metal component plays an important role in the strength of the seal. Microstructural analysis of as-sealed specimens revealed that an interfacial reaction zone forms during joining, and it appears that the thickness and composition of this layer are the dominant parameters that control joint strength. In this paper the details of the seal test are reported. The results have proven particularly significant in the development of the next-generation stack design. Supporting microstructural and chemical analyses collected on the test specimens are also presented and used to interpret the seal test results in an effort to identify the necessary steps toward improving glass pSOFC seals.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call