Abstract

This article, written by Special Publications Editor Adam Wilson, contains highlights of paper SPE 173913, “Run-Life Improvement by Implementation of Artificial-Lift- Systems Failure Classification and Root-Cause Failure Classification,” by Edward Rubiano, José Luis Martin, Jesus Prada, Manuel Monroy, Laura Labrador, Jonathan Celis, and Jahir Gutierrez, Oxy, and Michel Bohorquez, Ecopetrol, prepared for the 2015 SPE Artificial Lift Conference—Latin America and Caribbean, Salvador, Brazil, 27–28 May. The paper has not been peer reviewed. This paper describes a methodology for classification of artificial-lift-system (ALS) failures and addition of a commonly used root-cause failure classification. This methodology was applied to different ALSs such as beam pumps (BPs), progressing cavity pumps (PCPs), electrical submersible pumps (ESPs), and electrical submersible progressing cavity pumps (ESPCPs). The starting point was the definition of the boundaries of each system. Then, each job in the well was defined as (1) a failure, (2) a failure, non-ALS, or (3) no failure, in order to look for ways to improve run life. Introduction La Cira-Infantas oil field is in the Middle Magdalena Valley in Colombia (Fig. 1). The vast majority of the wells are completed with 7-in. production casing and perforated with 5 shots/ft with no sand-control completion in place, and then the ALS is installed. ALS in La Cira-Infantas From the beginning of the activity in La Cira-Infantas, almost 100 years ago, several ALSs have been used to produce fluids from the wells. Since 2005, the field has offered different conditions, depending on the mature state of the waterflooding— high water percentage, high and low flow rates, free gas, and corrosive fluids. Currently, ALSs such as BPs, PCPs, ESPs, and ESPCPs are used for producing the total fluid of the field. Failure Analysis The root-cause failure-analysis (RCFA) process used in La Cira-Infantas has the objective of finding the real cause of a given failure and identifying effective solutions to prevent a recurrence of the failure. The steps for the RCFA are as follows. Initial Diagnosis and Failure Confirmation. When an ALS ceases to lift the expected production, specific procedures are performed to try to restart the system. If production is not re-established, a downhole failure is confirmed. Pulling Equipment From the Well. Mechanical and electrical tests are performed to determine ALS condition. Tubing is tested for leaks. As equipment is pulled, each part of the ALS is inspected carefully and qualitative measurements are taken.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call