Abstract

A procedure was developed for the determination of residual monomers in polycarboxylate superplasticizer by reversed-phase high performance liquid chromatography. Seven kinds of residual monomers were quantitatively determined on a SinoChrom ODS-BP (C18) column and UV detector at 205 nm. The mobile phases which were used to determine micromolecular monomers were composed of acetonitrile and phosphate buffer solution (0.05 mol L−1, pH = 3) in the ratio of 8:92 (v/v). While the mobile phases for long side-chain monomers testing were composed of acetonitrile and phosphate buffer solution (0.05 mol L−1, pH = 6.5) in the ratio of 40:60 (v/v). The linear response ranged from 4.0 × 10−6–2.0 × 10−3 mol L−1. The detection limit was 0.12 × 10−5–0.8 × 10−5 mol L−1. Determination of real samples showed that relative standard deviation of high conversion rate samples was 3.1–8.7% and standard addition recovery ratio was 91.5–102.8%. While the relative standard deviation of low conversion rate samples was less than or close to 1% and the standard addition recovery ratio was 96.3–103.1%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.