Abstract
A reverse phase high performance liquid chromatography method was developed for simultaneous estimation of nitazoxanide and ofloxacin in tablet formulation. The separation and quantification was achieved by Hiq Sil C18V Size 4.6 mm Ø *250 mm column in isocratic mode, with mobile phase consisting of acetonitrile-methanol-0.4 M citric acid, (60:30:10, v/v/v). Citric acid used to stabilize nitazoxanide and ofloxacin in mobile phase. The mobile phase was pumped at a rate of 0.6 ml/min and the detection was carried out at 304 nm. The retention time of ofloxacin and nitazoxanide was found to be 3.122 and 5.902 min, respectively. The method was validated for linearity, accuracy, and precision. Linearity for ofloxacin and nitazoxanide were in the range 2-36 μg/ml and 5-90 μg/ml, respectively. The developed method was found to be accurate, precise and selective for simultaneous estimation of ofloxacin and nitazoxanide in tablets.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.