Abstract
This paper presents a novel method based on Magnetic Equivalent Circuit (MEC) to model the wound rotor three-phase induction machine under healthy and faulty conditions. Different parameters of machine such as the number of poles, number of slots, winding configuration and dimension can be selected based on designed properties of a given machine. Internal phase to phase fault is also detected by stator current signature analysis in dq frame. Saturation effect is modeled by a tunable function as well as the core nonlinearity characteristic is considered. Finally, Finite Element Method (FEM) is used to evaluate the accuracy of the proposed MEC model. Short computational time of MEC method shows that this model is suitable for electrical machine modeling and analysis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.