Abstract
Selected test results are presented for an annular gas seal using a smooth rotor and a hole-pattern-roughness stator for a supply pressure of 70 bar, three pressure ratios, three speeds up to 20,000 rpm, two clearances, and three preswirl ratios. Dynamic data include frequency-dependent direct and cross-coupled stiffness and damping coefficients. Static data include leakage and upstream and downstream pressures and temperatures. Very good agreements are found between measurements and predictions from a two-control-volume bulk-flow model.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.