Abstract

This case study presents two diagnostic methods for the detection of broken bars in induction motors with squirrel-cage type rotors: FFT method and wavelet method. The FFT method allows detecting broken rotor bar when the motor operates under a load, but if the machine is decoupled from the mechanical load, the side band components associated with broken bars do not appear. The WT is a powerful signal-processing tool used in power systems and other areas. New wavelet-based detection methods that are focused on the analysis of the startup current have been proposed for the detection of broken bars. Since the transient stator current signal is not periodic, it is not amenable to analyze the signal by FFT method. In addition, it is impossible to estimate the time of the fault occurrence using the FFT. In this paper, our main goal is to find out the advantages of wavelet transform method compared to Fourier transform method in rotor failure detection of induction motors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.