The subject of on-line detection of rotor cage faults in three-phase induction motors is discussed, and a noninvasive approach, based on computer-aided monitoring of the stator current Park's vector, is introduced, Both simulation and laboratory test results demonstrate the effectiveness of the proposed technique, for detecting broken rotor bars or end-rings in operating three-phase induction machines. On-site tests conducted in a power plant, using the diagnostic instrumentation system developed, are also reported.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.