Abstract

PurposeTo determine the cost-effectiveness of knotted (KT) versus knotless (KL) methods for rotator cuff surgical repair and to assess differences in patients’ outcomes.MethodsWe retrospectively identified all patients who underwent arthroscopic rotator cuff repair at 1 institution by 1 surgeon over 2 6-month periods of time (KT technique from August 1, 2013, through January 31, 2014; and KL technique from December 1, 2014, through May 31, 2015) to calculate the direct and indirect costs associated with arthroscopic KT or KL suture bridge rotator cuff repair. Patient demographics, number of anchors used, tendons repaired, procedure time, operative time, and clinical results were also evaluated. We used univariate generalized linear models with a Gaussian distribution for assessment scores and total and implant cost data.ResultsWe identified 87 patients for inclusion during the 2 time frames (35 KT, 54 KL). After excluding patients for tear size < 4 cm2 (n = 42), ≤ 3 anchors (n = 5), revision surgery (n = 1), and those in whom additional procedures were performed (n = 2), 37 eligible subjects remained (nKT = 15, nKL = 22). Median implant costs were statistically significantly higher in the KL group than in the KT group (MKL = $2,127, MKT = $1,520, β = 413.7, 95% CI: 242.8, 584.6, P < .01), and more anchors were used in the KL group, with KT requiring a median of 4 anchors (IQR: 4, 5) and KL requiring a median of 5 anchors (IQR: 5, 5, P = .02). Procedure time was cut in half with KL repair (estimated 43.5 minutes) versus KT repair (80 minutes) (β = 0.5, 95% CI: 0.4, 0.6, P < .001). Operating room time also was reduced by approximately 40% (79.5 minutes for KL; 121 minutes for KT [β = 0.6, CI: 0.6, 0.7, P < .001]). Once operating room costs were considered, median costs were found to be significantly lower in the KL group (MKL = $3788.40, MKT = $4262.90, β = –492.1, 95% CI: –840.0, –144.1, P < .01). No statistically significant differences were found between groups in mean preoperative, postoperative or postpreoperative differences in the visual analog scale, Simple Shoulder Test, American Shoulder and Elbow Surgeons, or University of California at Los Angeles scores (P > 0.05 for all).ConclusionsDespite using more anchors and incurring higher implant costs, the KL technique for rotator cuff repair required less surgical procedure time and cost less overall than the KT technique and resulted in equivalent clinical results.Level of EvidenceLevel IV Economic and Decision Analyses.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.