Abstract
AbstractThe power consumption of axial flow fans may account for more than 1% of the rated power output of the power generating unit, so it is of benefit to the energy efficiency of the power generating unit to propose an operation adjustment approach to axial flow fans. On the basis of representative 2 × 600 MW direct dry cooling generating units, a computational model of air‐side flow and heat transfer of an air‐cooled condenser (ACC) combined with exhaust steam condensation is developed, by which the airflow rate, inlet air temperature of ACCs, the power consumption of axial flow fans, turbine backpressure, and net power output of power generating units at various wind speeds and in various wind directions are obtained. The results show that the net power output in the presence of winds always decreases when the rational speeds of the first upwind row axial flow fans increase from the rated speed of 79 rpm by 10% to 86.9 rpm. However, the net power output will increase in various wind directions if the rational speeds of all the fans except the upwind first row fans increase to 86.9 rpm. This can contribute to the optimal operation of the ACC by rotational speed adjustment of axial flow fans.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.