Abstract

ABSTRACTThis article presents the results of an experimental study on the rotational behavior of degraded Chinese traditional mortise-tenon joints with different degradation types and different degradation degrees. Six joint specimens degraded through artificially simulated method, were tested by reversed cyclic loading, from which the moment-rotation curves were obtained. The results indicated that the rotational behavior of these joints is semi-rigid, the hysteretic curve shapes of degraded joints are same to that of joint without degradation. The maximum moment, yield moment, and initial rotational stiffness of degraded joints decreases as the degraded degree increases, whose empirical degradation relationships were obtained based on the test data. A hysteretic model for degraded traditional mortise tenon joints was proposed. Experimental results were used to validate the proposed hysteretic model. Good agreement between predictions and tests was observed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.