Abstract

An electric rotating machine can be defined as any form of apparatus which has a rotating member and generates, converts, transforms, or modifies electric power, such as a motor, generator, or synchronous generator. Although there are many variations, the two basic rotating machine types are synchronous and induction machines. The recent increasing use of rotating machines among other distributed generators is due to a number of advantages including peak shaving, improvement of the quality of power and reliability, power efficiency, environmental friendliness among others. Despite the above mentioned benefits of distributed power generation in the power grid, they have one major drawback, unintentional islanding. If this islanding condition is not detected in time or goes undetected, the distributed generator loses synchronism with the rest of the utility supply. This may lead to out of phase reconnection of the two systems and thus destroying the distributed generators and even lead to a total blackout in the power system. Again, upon the occurrence of an island, rotating machine based generators have another possible consequence of self-excitation. There is therefore need of fast detection of islanding condition especially when rotating machine based generators are integrated into the main power grid. There are many islanding detection methods and each has its merits and demerits. Their usage depends on certain factors including type of distributed generation in consideration and cost of implementation. Furthermore, the rotating machine based generators have the capability of sustaining an island. This makes the islanding detection and protection of these generators a bit challenging when compared with inverter based generators. This paper presents a passive islanding detection method, fuzzy logic algorithm, particularly on rotating machine based generators and its results analyzed under different conditions. After this analysis, it is concluded that the proposed method for islanding detection for rotating machine based generators is robust and accurate when implemented in the distribution network. This is because fuzzy logic control helps to improve the interpretability of knowledge-based classifiers through its semantics that provide insight in the classifier structure and decision-making process over crisp classifiers.

Highlights

  • The increase of distributed resources in the electric utility systems is being witnessed currently due to recent and ongoing technological, social, economical and environmental aspects [1]

  • These include and not limited to; Small hydraulic units, with and without governor, driving synchronous generators with automatic voltage regulators, diesel units with governors and voltage regulators, wind turbines connected to the system through directly coupled induction generators, and Wind turbines connected to the system through doubly-fed induction generators [3]

  • The rate of change of power (ROCOP) was measured and its result is as shown in figure 8 below

Read more

Summary

Introduction

The increase of distributed resources in the electric utility systems is being witnessed currently due to recent and ongoing technological, social, economical and environmental aspects [1]. This trend has significantly brought many psitive and negative effects to both the power system infrastructure and the electric power market at large. There is a variety of rotating machine-based DG technologies in use currently These include and not limited to; Small hydraulic units, with and without governor, driving synchronous generators with automatic voltage regulators, diesel units with governors and voltage regulators, wind turbines connected to the system through directly coupled induction generators, and Wind turbines connected to the system through doubly-fed induction generators [3]. These include peak saving when most loads are connected into the system, saving on the costs of upgrading the transmision and distribution part of the grid, environmental friendliness of most DGs among other merits

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.