Abstract

The purpose of this study was to evaluate a stainless steel (CT-5) and zirconium nitride coated (KiS) microsurgical ultrasonic instrument with regard to possible root-end fracture production during retropreparation. Forty extracted human central incisors were prepared in a crown-down fashion. Canals were obturated with gutta-percha by lateral condensation. Root-ends were resected. Teeth were placed in methylene blue for 48 h and evaluated by three independent evaluators under microscope. Teeth with existing fractures were eliminated from the study. The remaining teeth were randomly divided into two equal groups. Group A was prepared with the CT-5 tip and Group B with the KiS tip. Preparation time was recorded for all roots. The teeth were again immersed in methylene blue for 48 h and reevaluated. No root-end fractures were produced by either the KiS or CT-5 microsurgical ultrasonic instruments.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.