Abstract

Abstract The present study emphasizes the possible modes of failure of a unitized regenerative fuel cell (URFC) when operated in fuel cell as well as in electrolysis mode at different temperatures viz. 30 °C and 60 °C. The carbon based catalyst (Pt/C) and diffusion layers are used to characterize the degradation of the URFCs. The electrolysis mode of operation is found to dominate the root cause of failure with increase in temperature. Agglomeration and loss of catalyst along with delamination of electrode from membrane are observed. Membrane degradation owing to it's structural as well as chemical damage is seen to be prominent at higher temperature. Characterization techniques such as SEM, TEM and ICP-AES confirm the study showcasing the effect.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.