Abstract

This paper investigates the root cause of an unexpected brittle transverse cracking in a carbon steel slab. The observed failure in the form of a deep and relatively straight transverse crack appeared in the middle of the slab during storage before hot rolling. The microstructure of the failed slab, and more specifically that in the vicinity of the crack were studied using electron and optical microscopy. Energy-dispersive X-ray spectroscopy (EDS) was used to study the chemical composition of different phases, observed in the microstructure. Analysis of the chemical composition of the alloy showed that chromium and nitrogen contents of the failed slab were out of standard range. Results of fractography showed that grain boundary de-cohesion and trans-granular fracture were dominant features in the fracture surface. Correlations between microstructure, processing parameters, and observed abnormal brittle fracture were discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.