Abstract

BackgroundRadiographic analysis of tooth morphology is mandatory for accurate calibration of the degree of canal curvature angle and radiographic working length to its real dimensions in case difficulty assessment protocols. This study aimed to determine the impact of the degree of root canal curvature angle on maintaining the real working length and the original canal axis of prepared root canals using a reciprocating rotary instrumentation technique.MethodsRadiographic image analysis was performed on 60 extracted single-rooted human premolar teeth with a moderate canal curvature (10°–25°) and severe canal curvature (26°–70°). Working length and longitudinal canal axis were determined using cone-beam computed tomography (CBCT) and digital periapical radiography. The real canal length was determined by subtracting 0.5 mm from the actual canal length. Root canals were prepared using the WaveOne Gold reciprocating file (Dentsply Maillefer, Ballaigues, Switzerland).ResultsThere was no significant relation of the degree of canal curvature angle to the accuracy of radiographic working length estimated on CBCT and digital periapical radiographic techniques (P > 0.05). Postinstrumentation changes in the original canal axis between moderate and severe canal curvature angles, assessed on CBCT and periapical digital radiographic images were statistically non-significant (P > 0.05).ConclusionsA standardized digital periapical radiographic method performed similarly to the CBCT technique near to its true working length. No significant interaction exists between the diagnostic working length estimation, postoperative root canal axis modification, and the degree of canal curvature angle, using reciprocating rotary instrumentation technique.

Highlights

  • Radiographic analysis of tooth morphology is mandatory for accurate calibration of the degree of canal curvature angle and radiographic working length to its real dimensions in case difficulty assessment protocols

  • Root canal cleaning and shaping is a fundamental step in clinical endodontics, and it is directly related to subsequent disinfection and filling procedures

  • Uncentered and extensive canal axis modification can result in iatrogenic errors such as strip perforation, ledge formation, and insufficient disinfection of prepared root canals [3, 4]

Read more

Summary

Introduction

Radiographic analysis of tooth morphology is mandatory for accurate calibration of the degree of canal curvature angle and radiographic working length to its real dimensions in case difficulty assessment protocols. Root canal cleaning and shaping is a fundamental step in clinical endodontics, and it is directly related to subsequent disinfection and filling procedures. It must enhance a funnel shape from the cervical to the apical portion, preserving the preoperative canal curvature. Faraj BMC Oral Health (2021) 21:90 angle and the location of the major apical foramen [1, 2]. These technical objectives are of great significance and have always been much more challenging in curved root canals. Intraoral radiography has some limitations because of its 2-dimensional nature, information may be difficult to interpret, especially in challenging conditions when the anatomy of the root canal system is complex [6, 7]

Objectives
Methods
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call