Abstract
It is already recognised that heavy-atom-induced, room-temperature phosphorescence can be used to determine pindolol in pharmaceutical samples and biological fluids. We describe here a new, simple, rapid and selective development of this technique. The phosphorescence signals derive from the interaction of pindolol with a relatively high concentration of heavy-atom salts in the presence of sodium sulphite as oxygen scavenger. Phosphorescence was registered in the presence of 1.2 M potassium iodide, 15 mM sodium sulphite and 30% v/v methanol at 450 nm, exciting at 285 nm. The detection limit was 21.1 ng mL(-1). The method has been successfully applied to the determination of pindolol in commercial pharmaceutical tablets, urine and blood serum.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.