Abstract

A 68-year-old man was admitted with intermittent chest tightness. Coronary angiography revealed subtotal occlusion of right coronary artery (RCA). After successful stenting from middle to proximal RCA with two Cypher stents, angiography showed a "Rolling filling defect" at distal aneurysmal dilatation of RCA. Intravascular ultrasound (IVUS) confirmed the "Rolling filling defect" as a trapped air bubble just in RCA distal aneurysm. By using a 2.5 x 20 mm balloon anchoring at distal RCA, a 5Fr. ST01 catheter was advanced into distal RCA and aspirated the "Rolling filling defect" successfully. The case highlights the importance of preventing iatrogenic trapped air bubble in usual daily practice. Once it happens, several devices may utilize for aspiration including "5 in 6" aspiration technique or thrombo-suction catheters. Furthermore, IVUS can help for differential diagnosis in such scenario.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.