Abstract

Of 13,203 transfemoral diagnostic and therapeutic cardiac catheterization procedures performed between January 1, 1980 and December 31, 1990, 73 (0.55%) were complicated by pseudoaneurysm (PA) formation, and 15 (0.11%) by arteriovenous fistulas (AVF). The rate of PA increased progressively from 0.44% (1980-1987), to 0.59% (1987-1989), to 0.92% (1990), with no corresponding change in the incidence of AVF. The rising incidence of PA complicating transfemoral cardiac catheterization was associated closely with the use of larger diameter catheters and aggressive antiocoagulation during coronary interventions, but findings during surgical repair suggested that puncture of the superficial femoral (SFA), rather than the common femoral artery (CFA), was an important avoidable cause of some PA and AVF. A technique for fluoroscopic localization of the puncture site to avoid inadvertent SFA puncture and the associated increased risk of complication is proposed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.