Abstract

Automated blood culture (BC) system remains the best approach for early definitive management of sepsis. A retrospective analysis of samples received over 2 years was done to compare the sensitivity of single, paired and multiple BC sets. A total of 24,955 samples were received, of which 11,355 were single, 12,555 were paired and 1045 were multiple. BC sensitivity increased from 32.3% to 87% when samples increased from one to two, and a rise of another 13% with four sample sets (P < 0.0001). There is higher chance of missing positives if only a single BC sample was collected.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.