Abstract

Aim:The aim of the study was to evaluate efficacy of percutaneous computed tomography (CT)-guided radiofrequency ablation (RFA) of nidus in osteoid osteoma (OO).Materials and Methods:RFA was performed on fifty patients with clinically and radiologically diagnosed OO. RFA was done in the department of radio-diagnosis in our institute (a tertiary care providing institute in Ahmedabad, Western India). Ablation was performed by putting at an electrode tip (3–5 mm) into nidus under CT guidance with targeted temperature of 90°C for 3 min.Results:All procedures were technically successful. No immediate major or minor complications were observed. Complete clinical success was achieved in 46 patients. Only four patients required second intervention.Conclusion:Our experience indicates a 98% success rate. No major complications were noted.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.