Abstract
AIMTo investigate the efficacy and safety of a combination of sufentanil and propofol injection in patients undergoing endoscopic injection sclerotherapy (EIS) for esophageal varices (EVs).METHODSPatients with severe EVs who underwent EIS with sufentanil and propofol anesthesia between April 2016 and July 2016 at our hospital were reviewed. Although EIS and sequential therapy were performed under endotracheal intubation, we only evaluated the efficacy and safety of anesthesia for the first EIS procedure. Patients were intravenously treated with 0.5-1 μg/kg sufentanil. Anesthesia was induced with 1-2 mg/kg propofol and maintained using 2-5 mg/kg per hour of propofol. Information, regarding age, sex, weight, American Association of Anesthesiologists (ASA) physical status, Child-Turcotte-Pugh (CTP) classification, indications, preanesthetic problems, endoscopic procedure, successful completion of the procedure, anesthesia time, recovery time, and anesthetic agents, was recorded. Adverse events, including hypotension, hypertension, bradycardia, and hypoxia, were also noted.RESULTSPropofol and sufentanil anesthesia was provided in 182 procedures involving 140 men and 42 women aged 56.1 ± 11.7 years (range, 25-83 years). The patients weighed 71.4 ± 10.7 kg (range, 45-95 kg) and had ASA physical status classifications of II (79 patients) or III (103 patients). Ninety-five patients had a CTP classification of A and 87 had a CTP classification of B. Intravenous anesthesia was successful in all cases. The mean anesthesia time was 33.1 ± 5.8 min. The mean recovery time was 12.3 ± 3.7 min. Hypotension occurred in two patients (1.1%, 2/182). No patient showed hypertension during the endoscopic therapy procedure. Bradycardia occurred in one patient (0.5%, 1/182), and hypoxia occurred in one patient (0.5%, 1/182). All complications were easily treated with no adverse sequelae. All endoscopic procedures were completed successfully.CONCLUSIONThe combined use of propofol and sufentanil injection in endotracheal intubation-assisted EIS for EVs is effective and safe.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.