Abstract

IntroductionProstate-specific membrane antigen (PSMA) positron emission tomography/ computed tomography (PET-CT) is widely used as a staging tool for patients with prostate cancer (PCa). The objective of the study is to assess the diagnostic accuracy of 68Ga-PSMA-PET/CT for PCa, which may help us avoid unnecessary biopsies in patients with intermediate prostate-specific antigen (PSA) levels.Material and methodsIn this prospective study, 81 patients suspected of PCa, with either raised PSA between 4–20 ng/ml or abnormal digital rectal examination (DRE) findings were included. 68Ga-PSMA-PET/CT was performed for all patients followed by transrectal ultrasound (TRUS) guided prostate biopsy. SUVmax (maximum standardized uptake value) was measured and correlated with biopsy results.ResultsOut of 81 patients, 31 (38.3%) patients were found to have malignancy on biopsy. Median SUVmax of biopsy positive patients was 10.4 (IQR 6.5–16.1) and biopsy negative patients (n=50) was 3.5 (IQR 1–4.9), (p <0.001). At a cut-off of 6.15, 68GA-PSMA-PET/CT demonstrated sensitivity of 84%, specificity of 80%, positive predictive value of 72.2%, negative predictive value of 88.9% and accuracy of 81.5% with an AUC of 0.876 (95% CI: 0.799–0.953, p <0.001).ConclusionsThe 68Ga-PSMA-PET/CT helps to localize suspicious lesions and improving the detection of primary prostate cancer. Our findings indicate a significant correlation of SUVmax values with biopsy results. We were also able to determine a cut-off value of SUVmax below which prostate biopsy can be avoided in selected patients.