Abstract

The robustness of steel joints in fire is important for steel building structures because of the need to prevent progressive collapse. Stainless steel is widely used in building construction mainly because of its corrosion resistance, but it also possesses improved fire resistance compared with conventional non-alloy, fine grain structural steels. Extensive research performed on the robustness of steel joints in fire has revealed that failure at elevated temperature may be controlled by bolt shear for fin plate and web cleat connections. Hence, this study focussed on the use of stainless steel in experimental tests conducted on fin plate and web cleat connections at high temperatures. In addition, this study investigated the use of a component-based model to predict connection performance at elevated temperature.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.