Abstract

BackgroundThe detection of weak signals and selection of single particles from low-contrast micrographs of frozen hydrated biomolecules by cryo-electron microscopy (cryo-EM) represents a major practical bottleneck in cryo-EM data analysis. Template-based particle picking by an objective function using fast local correlation (FLC) allows computational extraction of a large number of candidate particles from micrographs. Another independent objective function based on maximum likelihood estimates (MLE) can be used to align the images and verify the presence of a signal in the selected particles. Despite the widespread applications of the two objective functions, an optimal combination of their utilities has not been exploited. Here we propose a bi-objective function (BOF) approach that combines both FLC and MLE and explore the potential advantages and limitations of BOF in signal detection from cryo-EM data.ResultsThe robustness of the BOF strategy in particle selection and verification was systematically examined with both simulated and experimental cryo-EM data. We investigated how the performance of the BOF approach is quantitatively affected by the signal-to-noise ratio (SNR) of cryo-EM data and by the choice of initialization for FLC and MLE. We quantitatively pinpointed the critical SNR (~ 0.005), at which the BOF approach starts losing its ability to select and verify particles reliably. We found that the use of a Gaussian model to initialize the MLE suppresses the adverse effects of reference dependency in the FLC function used for template-matching.ConclusionThe BOF approach, which combines two distinct objective functions, provides a sensitive way to verify particles for downstream cryo-EM structure analysis. Importantly, reference dependency of the FLC does not necessarily transfer to the MLE, enabling the robust detection of weak signals. Our insights into the numerical behavior of the BOF approach can be used to improve automation efficiency in the cryo-EM data processing pipeline for high-resolution structural determination.

Highlights

  • The detection of weak signals and selection of single particles from low-contrast micrographs of frozen hydrated biomolecules by cryo-electron microscopy represents a major practical bottleneck in cryo-EM data analysis

  • We systematically evaluated how the performance of the bi-objective function (BOF) approach is affected by three variables: (1) the signal-to-noise ratio (SNR) of the cryo-EM data, (2) the choices of the template used for particle picking, and (3) the initialization reference used in maximum likelihood estimates (MLE) alignment for signal verification

  • This average closely resembled the HIV-1 envelope glycoprotein (Env) trimer template used for particle picking (Fig. 2d), and apparently resulted from reference dependency in template-based particle picking by the fast local correlation (FLC)

Read more

Summary

Introduction

The detection of weak signals and selection of single particles from low-contrast micrographs of frozen hydrated biomolecules by cryo-electron microscopy (cryo-EM) represents a major practical bottleneck in cryo-EM data analysis. Template-based particle picking by an objective function using fast local correlation (FLC) allows computational extraction of a large number of candidate particles from micrographs. Another independent objective function based on maximum likelihood estimates (MLE) can be used to align the images and verify the presence of a signal in the selected particles. The determination of cryo-EM structures of biomolecules at high resolution requires that a large number of single-particle images, often on the scale of hundreds of thousands to a million, are acquired, aligned and averaged to remove background image noise in signal reconstruction

Methods
Results
Discussion
Conclusion