Abstract

AbstractThis paper describes an experimental investigation on the resistance and failure mode of four precast concrete frames. Each frame comprised a middle beam-column joint, a double-span beam, and two side columns. Two parameters, namely, reinforcement detailing in the beam-column joint and dimensions of the side columns, were investigated in the experimental program. Frame specimens were loaded on the middle joint by a vertical servohydraulic actuator, and corresponding horizontal reaction forces were recorded through load cells connected to the side columns. Experimental results and observations indicate that precast concrete frames were capable of developing compressive arch action (CAA) at the initial loading stage. However, frames with smaller side columns exhibited shear failure in the side joint. This hindered the development of catenary action in the bridging beam. By increasing the dimensions of the side columns, significant catenary action developed in the frames, and eventually flexural fail...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.