Abstract

Accordance with a new EN 1992 the robustness of the structural systems must be analyzed. When applying proposed new strategy, it has been verified that the structure has sufficient redundancy and possibility to mobilize so-called alternate load path (AP-method). Paper presents a modified complex method for robustness estimation in case of the RC-structural systems. Proposed pseudo-static method based on the energy-saving approach. Paper also presents a full probabilistic pseudo-static nonlinear method which was developed for structural robustness assessment, taking into account the statistical variability of the materials properties and, as a consequence, parameters of the plastic hinges and possible failure modes.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.