Abstract

The ability to monitor the respiratory rate, one of the vital signs, is extremely important for the medical treatment, healthcare and fitness sectors. In many situations, mobile methods, which allow users to undertake everyday activities, are required. However, current monitoring systems can be obtrusive, requiring users to wear respiration belts or nasal probes. Alternatively, contactless digital image sensor based remote-photoplethysmography (PPG) can be used. However, remote PPG requires an ambient source of light, and does not work properly in dark places or under varying lighting conditions. Recent advances in thermographic systems have shrunk their size, weight and cost, to the point where it is possible to create smart-phone based respiration rate monitoring devices that are not affected by lighting conditions. However, mobile thermal imaging is challenged in scenes with high thermal dynamic ranges (e.g. due to the different environmental temperature distributions indoors and outdoors). This challenge is further amplified by general problems such as motion artifacts and low spatial resolution, leading to unreliable breathing signals. In this paper, we propose a novel and robust approach for respiration tracking which compensates for the negative effects of variations in the ambient temperature and motion artifacts and can accurately extract breathing rates in highly dynamic thermal scenes. The approach is based on tracking the nostril of the user and using local temperature variations to infer inhalation and exhalation cycles. It has three main contributions. The first is a novel Optimal Quantization technique which adaptively constructs a color mapping of absolute temperature to improve segmentation, classification and tracking. The second is the Thermal Gradient Flow method that computes thermal gradient magnitude maps to enhance the accuracy of the nostril region tracking. Finally, we introduce the Thermal Voxel method to increase the reliability of the captured respiration signals compared to the traditional averaging method. We demonstrate the extreme robustness of our system to track the nostril-region and measure the respiratory rate by evaluating it during controlled respiration exercises in high thermal dynamic scenes (e.g. strong correlation (r = 0.9987) with the ground truth from the respiration-belt sensor). We also demonstrate how our algorithm outperformed standard algorithms in settings with different amounts of environmental thermal changes and human motion. We open the tracked ROI sequences of the datasets collected for these studies (i.e. under both controlled and unconstrained real-world settings) to the community to foster work in this area.

Highlights

  • Monitoring respiratory rate plays a key role in a range of applications that span from direct diagnosis of, and treatment for, lung problems and cardiovascular conditions to supporting a person’s psychological needs [1,2]

  • To have mobile, ubiquitous systems that operate in general environment and not merely controlled indoor-laboratory settings, we have to confront the following key challenges: Challenge 1: High thermal dynamic range scenes Despite our homoeothermic characteristics, temperature distribution on the cutaneous skin of the human face changes with the ambient temperature

  • In the case of tracking during physical activity (i.e. Dataset 3: high thermal dynamic range & motion artifacts), our approach performed significantly better than all the other methods, showing its robustness in nostril-region tracking to challenges present in everyday settings

Read more

Summary

Introduction

Monitoring respiratory rate plays a key role in a range of applications that span from direct diagnosis of, and treatment for, lung problems (e.g. hyperventilation, apnea and interstitial lung disease) and cardiovascular conditions to supporting a person’s psychological needs (e.g. stress, anxiety regulation) [1,2]. Despite its importance, it has been largely disregarded in real world healthcare technology applications [3]. This is unable to adapt to the dynamic situation here in which the temperature falls below 28°C in many parts of the image

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.