Abstract

In this paper, a nominal sensor placement methodology for leak location in water distribution networks is presented. To reduce the size and the complexity of the optimization problem a clustering technique is combined with the nominal sensor placement methodology. Some of the pressure sensor placement methods for leak detection and location in water distribution networks are based on the pressure sensitivity matrix analysis. This matrix depends on the network demands, which are nondeterministic, and the leak magnitudes, that are unknown. The robustness of the nominal sensor placement methodology is investigated against the fault sensitivity matrix uncertainty. Providing upon the dependency of the leak location procedure on the network operating point, the nominal sensor placement problem is then reformulated as a multi-objective optimization for which Pareto optimal solutions are generated. The robustness study as well as the resulting robust sensor placement methodology are illustrated by means of a small academic network as well as a district metered area in the Barcelona water distribution network.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.