Abstract

In this paper, we present a robust control strategy which is well adapted to parallel connected Forward/Buck converters. It is based on a non-linear controller which uses the advantages offered by sliding mode control and peak current techniques. This control offers fixed frequency control without using equivalent control calculation, synchronized ramp or variable hysteresis bandwidth. It also provides good robustness depending on variations of load parameters. A model of the system is developed which allows us to study the system independently of the module number that constitutes the structure. The controllability of the system is discussed and an analysis of the current behavior is provided.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.