Abstract
In this paper, a robust fault detection problem is investigated for a permanent magnet synchronous motor (PMSM). By using the adaptive control and the sliding-mode control strategies, an observer is presented for estimating the amplitude demagnetization fault problem under inductance disturbance. The proposed method can effectively attenuate the inductance disturbance of the PMSM by the sliding-mode strategy. And the adaptive control estimation algorithm is adopted for guaranteeing that the real-time detection of demagnetization flux can be realized. The convergency is obtained by the Lyapunov stability theory. Finally, simulation is given for demonstrating the feasibility and effectiveness of the proposed method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.