Abstract

Abstract This paper deals with the design of a robust hybrid observer for switched linear systems with unknown inputs and modeling error. The proposed observer is synthesized for the task of robust fault detection and concerns the case when the active mode is unknown. The basic idea of our approach is to formulate the design of the robust fault detection observer as a H∞ model-matching problem. Then, some results of H∞ optimization are exploited and an LMI solution procedure is proposed to synthesize the desired robust observer.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.