Abstract

PurposeMulti‐phase PCASL has been proposed as a means to achieve accurate perfusion quantification that is robust to imperfect shim in the labeling plane. However, there exists a bias in the estimation process that is a function of noise in the data. In this work, this bias is characterized and then addressed in animal and human data.MethodsThe proposed algorithm to overcome bias uses the initial biased voxel‐wise estimate of phase tracking error to cluster regions with different off‐resonance phase shifts, from which a high‐SNR estimate of regional phase offset is derived. Simulations were used to predict the bias expected at typical SNR. Multi‐phase PCASL in 3 rat strains (n = 21) at 9.4 T was considered, along with 20 human subjects previously imaged using ASL at 3 T. The algorithm was extended to include estimation of arterial blood flow velocity.ResultsBased on simulations, a perfusion estimation bias of 6‐8% was expected using 8‐phase data at typical SNR. This bias was eliminated when a high‐precision estimate of phase error was available. In the preclinical data, the bias‐corrected measure of perfusion (107 ± 14 mL/100g/min) was lower than the standard analysis (116 ± 14 mL/100g/min), corresponding to a mean observed bias across strains of 8.0%. In the human data, bias correction resulted in a 15% decrease in the estimate of perfusion.ConclusionsUsing a retrospective algorithmic approach, it was possible to exploit common information found in multiple voxels within a whole region of the brain, offering superior SNR and thus overcoming the bias in perfusion quantification from multi‐phase PCASL.

Highlights

  • Funding informationOxford Cancer Research UK/EPSRC Cancer Imaging Centre, Grant/Award Number: C5255/A16466; Cancer Research UK, Grant/Award Number: C5255/A15935; EPSRC, Grant/Award Number: EP/ P012361/1; Wellcome Trust, Grant/Award Number: 203139/Z/16/Z

  • Pseudo‐continuous labeling is widely accepted as the preferred scheme for ASL perfusion imaging due to superior signal‐to‐noise ratio (SNR) over pulsed variants

  • Using a retrospective algorithmic approach, it was possible to exploit common information found in multiple voxels within a whole region of the brain, offering superior SNR and overcoming the bias in perfusion quantification from multi‐phase PCASL

Read more

Summary

Funding information

Oxford Cancer Research UK/EPSRC Cancer Imaging Centre, Grant/Award Number: C5255/A16466; Cancer Research UK, Grant/Award Number: C5255/A15935; EPSRC, Grant/Award Number: EP/ P012361/1; Wellcome Trust, Grant/Award Number: 203139/Z/16/Z. There exists a bias in the estimation process that is a function of noise in the data. Simulations were used to predict the bias expected at typical SNR. Results: Based on simulations, a perfusion estimation bias of 6‐8% was expected using 8‐phase data at typical SNR. This bias was eliminated when a high‐precision estimate of phase error was available. Conclusions: Using a retrospective algorithmic approach, it was possible to exploit common information found in multiple voxels within a whole region of the brain, offering superior SNR and overcoming the bias in perfusion quantification from multi‐phase PCASL. KEYWORDS estimation bias, multi‐phase pseudo‐continuous arterial spin labeling, perfusion quantification, supervoxel clustering

| INTRODUCTION
| METHODS
| RESULTS
Findings
| DISCUSSION
| CONCLUSION
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.